200mm 300mm 400mm 500mm 600mm 700mm 800mm diameter maintenance-free circular guide
The FDA arc guide rail produced by this product can be a structural form of any combination of radius, arc, and straight lines. It is mainly used in production lines and automated production lines in the advertising industry. The characteristics of this product are that it does not require oil filling, does not rust, and has low noise.
1. Features of the curved guide rails produced by the company: It can be used in dirty environments, very clean clean rooms, and vacuum environments. The material can be made of G1/G8/G3 and other materials marked by the company. Standard products, 3D data can also be provided.
2. Various parts for arc guide rails can be sold separately.
3. The reducer and servo motor can be directly installed on the arc guide rail. The arc guide rail shapes provided by YOSO are triangle/quadrangle/ellipse/two-row ellipse, etc.
4. Special-shaped guide rails can also be made, and the radius of each arc can also be used.
5. The guide rails can be made of materials G1/G3/G8 marked by the company. Depending on the customer’s usage environment, they can be used in clean rooms or vacuum rooms. They are almost non-magnetic and rust-free.
1. Figure 2 shows the standard FDA-RVR slider
2. During design and installation, most users will encounter products on the slider that exceed the standard slider length. In this case, they will increase the number of sliders and fix them with connecting plates. length (as shown in Figure 3), please note that this design and installation method is wrong, and the slider cannot run smoothly in the curve.
3. If you need to lengthen the slider, you should communicate with the relevant personnel of YOSO Company in advance when purchasing. YOSO Company will design the slider according to the customer’s requirements (as shown in Figure 4). It is worth noting that the length of the slider must be smaller than the matched arc guide rail. diameter.
4. Many people will ask how to connect to the motor. The reason why this question is not explained in the sample is because the application technology of each product is different. But for reference, the power and electrical connection method can be the same as that of the existing ring guide rail. As shown in Figure 1, the guide rail can be connected by using synchronous pulleys at both ends to match the synchronous belt. The two semicircular parts in the middle must be designed with additional accessories.
5. In addition, like FDA-RV products, FDA-RVR products can also be equipped with positioning blocks and synchronous belt connection block structures on the left and right sides. For details, please refer to the product FDA-RV connection method.
Nominal Model | FDA25RV+60(Arc Guide Parameters) | ||||||||||
W1 | M1 | Q | Q1 | Q2 | L0 | U | dixd2xh | C(kN) | Co(kN) | Weight kg |
|
FDA25RV+60/100R | 23 | 23 | 60 | 8 | 22.0 | 100 | 13.4 | 7x11x9 | 4.8 | 2.03 | |
FDA25RV+60/150R | 6 | 24.0 | 150 | 201 | |||||||
FDA25RV+60/200R | 4.5 | 170 | 200 | 26.8 | |||||||
FDA25RV+60/250R | 3 | 13.5 | 250 | 33.5 | |||||||
FDA25RV+60/300R | 2.5 | 11.0 | 300 | 40.2 | |||||||
FDA25RV+60/350R | 3 | 9.0 | 350 | 46.9 | |||||||
FDA25RV+60/400R | 2.1 | 93 | 400 | 53.6 | |||||||
FDA25RV+60/450R | 2 | 8.0 | 450 | 60.3 | |||||||
FDA25RV+60/500R | 1.6 | 71 | 500 | 67 | |||||||
FDA25RV+60/550R | 1.2 | 6.4 | 550 | 73.7 | |||||||
FDA25RV+60/600R | 1 | 5.8 | 600 | 80.4 | |||||||
FDA25RV+60/650R | 5.8 | 650 | 87.08 | ||||||||
FDA25RV+60/700R | 1.2 | 4.8 | 700 | 93.8 | |||||||
FDA25RV+60/750R | 1.2 | 4.8 | 750 | 100.5 | |||||||
FDA25RV+60/000R | 1.2 | 3.6 | 1000 | 134 | |||||||
FDA25RV+60/200R | 0.55 | 29 | 1200 | 160.8 | |||||||
FDA25RV+60/1250R | 29 | 1250 | 1675 | ||||||||
FDA25RV+60/1300R | 0.55 | 31 | 1300 | 174 | |||||||
FDA25RV+60/400R | 0.6 | 2.45 | 1400 | 188 | |||||||
FDA25RV+60/450R | 0.6 | 2.45 | 1450 | 194.3 | |||||||
FDA25RV+60/1850R | 0.48 | 2.46 | 1850 | 2479 | |||||||
FDA25RV+60/2000R | 0.60 | 210 | 2000 | 268 | |||||||
FDA25RV+60/2500R | 0.50 | 1.55 | 2500 | 335 | |||||||
FDA25RV+60/3000R | 0.40 | 1.20 | 3000 | 4019 | |||||||
Nominal Model | M | H3 | W | L | B | C | 4-S | d1xd2xh | C(kN) | Co(kN) | Weight kg |
FDA25RV+60/R | 36 | 3.88 | 85 | 105 | 60 | 60 | M8 | 7x11x9 | 4.8 | 2.03 | |
All specifications are the same size |
Nominal Model | FDA25RV+60(Arc Guide Parameters) | ||||||||||
W1 | M1 | Q | Q1 | Q2 | L0 | U | d1xd2xh | C(kN) | Co(kN) | Weight kg |
|
FDA25RV+90/100R | 23 | 23 | 90 | 8.00 | 370 | 141 | 29.3 | 7x11x9 | 4.8 | 2.03 | |
FDA25RV+90/150R | 6.00 | 26.0 | 212 | 43.9 | |||||||
FDA25RV+90/175R | 4.00 | 20.5 | 248 | 51.3 | |||||||
FDA25RV+90/200R | 3.50 | 16.6 | 283 | 58.6 | |||||||
FDA25RV+90/250R | 3.60 | 13.8 | 354 | 73.2 | |||||||
FDA25RV+90/300R | 3.00 | 12.0 | 424 | 879 | |||||||
FDA25RV+90/350R | 2.70 | 94 | 495 | 103 | |||||||
FDA25RV+90/400R | 2.00 | 8.6 | 566 | 1172 | |||||||
FDA25RV+90/500R | 1.80 | 72 | 707 | 146.4 | |||||||
FDA25RV+90/550R | 1.45 | 6.7 | 7778 | 161.1 | |||||||
FDA25RV+90/600R | 1.50 | 5.8 | 846 | 175.7 | |||||||
FDA25RV+90/700R | 1.45 | 6.7 | 9899 | 205 | |||||||
FDA25RV+90/750R | 1.30 | 4.6 | 1060.7 | 2197 | |||||||
FDA25RV+90/860R | 1.00 | 4.0 | 1216.2 | 251.9 | |||||||
FDA25RV+90/900R | 1.00 | 4.0 | 1272.8 | 263.6 | |||||||
FDA25RV+90/1000R | 0.80 | 3.4 | 1414.2 | 2929 | |||||||
FDA25RV+90/1513R | 0.6 | 2.96 | 21397 | 443.1 | |||||||
FDA25RV+90/2000R | 0.35 | 2.35 | 28284 | 585.8 | |||||||
FDA25RV+90/3000R | 0.3 | 149 | 4242.6 | 878.7 | |||||||
Nominal Model | M | H3 | W | L | B | C | 4-S | d1xd2xh | C(kN) | Co(kN) | Weight kg |
FDA25RV+90/R | 36 | 3.88 | 85 | 105 | 60 | 60 | M8 | 7x11x9 | 4.8 | 2.03 | |
All specifications are the same size |
Nominal Model | FDA25RV+60(Arc Guide Parameters) | ||||||||||
W1 | M1 | Q | Q1 | Q2 | L0 | U | dixd2xh | C(kN) | Co(kN) | Weight kg |
|
FDA25RV+180/75R | 23 | 23 | 60 | 10 | 35.0 | 150 | 75 | 7x11x9 | 4.8 | 2.03 | |
FDA25RV+180/80R | 8 | 370 | 160 | 80 | |||||||
FDA25RV+180/100R | 6 | 26.0 | 200 | 100 | |||||||
FDA25RV+180/125R | 75 | 275 | 250 | 125 | |||||||
FDA25RV+180/150R | 4 | 20.5 | 300 | 150 | |||||||
FDA25RV+180/160R | 6 | 21.0 | 320 | 160 | |||||||
FDA25RV+180/175R | 3.5 | 16.6 | 350 | 175 | |||||||
FDA25RV+180/175.5R | 4.5 | 213 | 350 | 175 | |||||||
FDA25RV+180/200R | 3.6 | 13.8 | 400 | 200 | |||||||
FDA25RV+180/250R | 3 | 12.0 | 500 | 250 | |||||||
FDA25RV+180/300R | 27 | 94 | 600 | 300 | |||||||
FDA25RV+180/310R | 4 | 172 | 620 | 310 | |||||||
FDA25RV+180/350R | 2 | 8.6 | 700 | 350 | |||||||
FDA25RV+180/355R | 2.7 | 97 | 710 | 355 | |||||||
FDA25RV+180/351R | 2.7 | 97 | 702 | 351 | |||||||
FDA25RV+180/400R | 2 | 8.8 | 800 | 400 | |||||||
FDA25RV+180/500R | 2 | 8.0 | 1000 | 500 | |||||||
FDA25RV+180/550R | 18 | 8.4 | 1100 | 550 | |||||||
FDA25RV+180/580R | 1.5 | 59 | 160 | 580 | |||||||
FDA25RV+180/600R | 1.5 | 59 | 1200 | 600 | |||||||
FDA25RV+180/700R | 1.17 | 6.6 | 1400 | 700 | |||||||
FDA25RV+180/750R | 2.6 | 4.6 | 1500 | 750 | |||||||
FDA25RV+180/800R | 1.2 | 4.8 | 1600 | 800 | |||||||
FDA25RV+180/900R | 07 | 3.8 | 1800 | 900 | |||||||
FDA25RV+180/1000R | 0.75 | 3.5 | 2000 | 1000 | |||||||
Nominal Model | M | H3 | W | L | B | C | 4-S | dixd2xh | C(kN) | Co(kN) | Weight kg |
FDA25RV+180/R | 36 | 3.88 | 85 | 105 | 60 | 60 | M8 | 7x11x9 | 4.8 | 2.03 | |
All specifications are the same size |
Copyright © Jingpeng Machinery&Equipment(Shanghai) Co.,Ltd All Rights Reserved